Tutorials

Proper Method to Produce Lobster-back Duct Bends

3 1 Beginner
One type of industrial component I have been involved with the design and manufacture of is lobster-back bends. This type of duct bend is made up of segments cut from flat sheets or plates, rolled into cylindrical parts, then assembled. These can be light sheet-metal or manufactured from thick plate. This quick tutorial is a supplement to the one I produced an outline of a method I have used modeling this type of component using Alibre Design. As this supplement concerns producing parts ready for manufacture and applies to whatever software you have used, that is not important as this short tutorial is to outline turning your modeled bend into the flat profile ready to be made into the completed bend. In this modern world, the bend parts will be cut out using CNC laser, or CNC Plasma cutting machines. Sometimes we produce the nc programs ourselves or we are required to produce the correct files for the laser / plasma department to program and cut out. Making the program to cut out the parts starts normally from a 2D dxf file at a scale of 1 : 1. This is the first part of the process that has to be correct. If you produce this dxf incorrectly the finished parts will be useless. Producing this at the right scale, 1 : 1 is different with different 3D cad applications, other problems can be caused by you working in different drawing units. If you are not doing the program, talk to the person who is to make sure you produce the dxf as required. Having a large quantity of wrongly cut parts is not a good thing

"Failsafe" ESPHome Fireplace Controller

0 0 Intermediate
When asked what smart switch to use to control their gas fireplace, you see a lot of replies "do you want to be one software bug away from your fireplace turning on?" Granted, modern gas fireplaces have safeties in place to prevent un-lit open valves, runaway heating, etc., but some people would still rather have a hardware switch standing between them and fire. This project aims to be the best of both worlds: by running 5v power to the low-voltage switch box holding my fireplace wall switch (in my case, this involved pulling 5-conductor thermostat wire using the existing 2-conductor wire), you can power an ESP board running ESPHome. By running the actual thermostat switch signal through both a DPST and a (ESPHome-controlled) 3v relay, we can be sure that the fireplace is only "active" if the manual switch is turned on.

botella.isg

0 0 Intermediate
botella con ensambles

2.2kW 3000RPM

0 0 Intermediate
2,2 kw 3000 RPM radial aspirator

assemblies

0 0 Beginner
framing assemble in rhino

may uon

0 0 Beginner
may uon quoccuong vietthanh machine